IFMBE Proceedings 37 - In Vitro Study Of The Correlation ...
MIRA valves with curved leaflets were tested in the aortic position under pulsatile-flow condition to find the design and The On-X valve has two straight half-disk leaflets, which opens to 90G*,with a relatively long support ring and inlet ... Retrieve Content

Aortic Valve On-x Pictures

Mechanical Versus Bioprosthetic Valve Replacement In Valvular ...
Mechanical Versus Bioprosthetic Valve Replacement in Valvular Heart Disease: A Systematic Review Abstract Background: Treatment options for valvular heart disease include valve replacement with a mechanical or ... Get Doc

Aortic Valve On-x Photos

Echocardiographic Assessment Of Prosthetic Valves
Echocardiographic assessment of Prosthetic Valves Michael H. Picard, M.D. Massachusetts General Hospital – valve dysfunction, regurgitation, endocarditis, Aortic echo instantaneous peak vs cath peak to peak Mitral: ... Return Doc

Aortic Valve On-x Images

Management Of Bicuspid aortic valve With Or Without ...
Aortic valve - Heart valve diseases - Aortic valve stenosis. T. he BAV is typically made of two unequal-sized leaflets . 1. or an On-X valsalva graft with a mechanical valve incorporated inside the valsalva graft. Mechanical valves have a reasona- ... Access Content

Cavoatrial Junction - Wikipedia, The Free Encyclopedia
The cavoatrial junction (CAJ) is the point at which the superior vena cava meets and melds into the superior wall of the cardiac right atrium. Both the superior and inferior vena cavae enter the right atrium, but only the superior entry is called the cavoatrial junction. ... Read Article

Heart Valve Replacements: Deciding Which To Use
Heart Valve Replacements. Once you have made the decision to have heart valve replacement surgery, Treating Aortic Regurgitation; Heart Valve Diseases; All About Open Heart Surgery and Recovery; Treatment Choices for Mitral Regurgitation; ... Read Article

Images of Aortic Valve On-x

VALVULAR HEART DISEASE Doppler Echocardiographic Evaluation ...
Concomitant prosthetic aortic valve regurgitation. The EOAof mitral prostheses is calculated by the yThe On-X valve has just one size for 27e29 mm and 31e33 mm prostheses. In addition, the strut and leaflets are identical for all sizes (25e33 mm); ... Return Doc

Pictures of Aortic Valve On-x


Orifice and visibility on X-ray film. in patients with a previously implanted aortic or mitral valve prosthesis which is no longer functioning adequately and Carpentier-Edwards PERIMOUNT Pericardial Bioprostheses must be kept moist at all times. ... Document Viewer


• ATS Medical • Edwards Lifesciences • Johnson & Johnson • Labcor Laboratory • Medtronic • On-X Life Technologies • Shiley Laboratories • Sorin Biomedica • St. Jude Medical • Sulzer Carbomedics ... Read Article

Aortic Valve On-x Pictures

IFMBE Proceedings 31 - Correlation Between Aortic Flow And ...
Aortic valve insufficiency, over 50 years experiences have been accumulated for developing a hemodynamically better On-X valve generates simple jet-type flow while the MIRA valve with circumferentially curved leaflet generates strong ... Fetch Doc

Images of Aortic Valve On-x

Surgery For Valvular Heart Disease - Circulation
Surgery for Valvular Heart Disease Reoperation of Left Heart Valve Bioprostheses According to and On-X Life Technologies. Patient Population Between 1976 and 2010, 3975 patients underwent bioprosthetic Isolated aortic valve replacement in North America comprising 108,687 ... View Doc

Images of Aortic Valve On-x

To Bridge Or Not To Bridge Periop Anticoagulation Management
To Bridge or Not to Bridge Periop Anticoagulation Management Don Weinshenker, MD Ambulatory Care Denver VAMC. Financial Disclosure Information Nothing to report. Patient with bi-leaflet aortic mechanical valve who will be undergoing an open AAA repair. 1. Proceed directly to surgery. 2. ... Fetch Document

Photos of Aortic Valve On-x

Small aortic Annulus: The Hydrodynamic Performances Of 5 ...
Evolving Technology Small aortic annulus: The hydrodynamic performances of 5 commercially available bileaflet mechanical valves Tomaso Bottio, MD ... Fetch Here

Aliasing - Wikipedia, The Free Encyclopedia
In signal processing and related disciplines, aliasing is an effect that causes different signals to become indistinguishable (or aliases of one another) when sampled. ... Read Article

Aortic Valve On-x Images

Impact Of Aortic Valve Replacement For Aortic Stenosis On ...
Impact of Aortic Valve Replacement for Aortic Stenosis on Dynamic Mitral Annular Motion and Geometry Haider J. Warraich, MDa, Robina Matyal, MDb, Remco Bergman, MDb, Philip E. Hess, MDb, ... Read Here

Images of Aortic Valve On-x

Reduced Anticoagulation After Mechanical Valve Replacement ...
Reduced Anticoagulation After Mechanical Valve Replacement: Interim Results from the PROACT Randomized FDA IDE Trial John D. Puskas, MD, FACS, FACC ... Get Document

Popular Videos - Heart valve & Valve Replacement - YouTube
By On-X Life Technologies. 15:26. Play next; Play now; Heart valve surgery - operation for replacement heart valves by wad maq. 2:31. Play next; heart valve surgery.heart valve repair surgery.aortic valve surgery.aortic valve replacement by Judith Taltonanga. 6:22. Play next; Play now; ... View Video

Aortic Valve On-x

A Symptomatic Patient With aortic, Mitral And Tricuspid valve ...
Www.escardio.org/valvular Valve specialists for valve patients Decision Making in Patients with Multivalvular Disease A Symptomatic Patient with Aortic, ... Get Content Here

Aortic Valve On-x

Comparison Of Human And Porcine aortic valves
Various features of the aortic valve were measured: circumference, length between the The average circumferences of the human and porcine aortic valves were 8.00 0.2 (SD) cm and 7.90 1.0 cm, respectively. The central point of coaptation in human valves was skewed toward the left coronary cusp, ... Read Here

Aortic Valve On-x

The Echocardiographic Assessment Of Prosthetic Heart Valves ...
1 The Echocardiographic Assessment of Prosthetic Heart Valves Introduction Approximately 100,000 artificial heart valves are implanted each year world-wide, of which 5 ... Retrieve Here

Aortic Valve On-x Pictures

Measurement Of Opening And Closing Angles Of Aortic In Vivo ...
Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: LOM of the On-X valve was assessed based on the consistently restricted motion of a leaflet or leaflets without using a cutoff because a decrease in ... Retrieve Here