Dr Trevor Malcolm Fayers - Dallas-Leipzig Valve
Dr Trevor Malcolm Fayers CURRICULUM VITAE July 2014 . Trevor Fayers Curriculum Vitae CURRENT POST: 2013: St Jude Trifecta Aortic Heart Valve: Canberra, Australia. 2013: Minimally Invasive Mitral Valve Surgery: Standard of Care. RACS Annual ... Access Full Source
Quantitative Assessment Of Paravalvular Regurgitation ...
Regurgitation following transcatheter aortic valve replacement Gareth Crouch1,2,4, Phillip J Tully2, Jayme Bennetts2, St Jude Medical Epic™ and Trifecta™, St Jude Medical Inc, Minnesota; Edwards Perimount Magna, Edwards Lifesciences, California USA. ... Document Viewer
Aortic Valve Replacement. - SCA
Aortic valve replacement with no previous history of an abnormal coagulation profile. performed using a 19-mm Trifecta St. Jude tissue valve. Severe aortic stenosis can cause the mechanical disruption of large von Willebrand factor ... Fetch Full Source
Portico Transcatheter Heart Valve
Valve manufactured by St. Jude Medical, which is spe-cially designed to improve the clinical results of tran- Trifecta aortic pericardial valve: results from a global, multi-center, prospective clinical study. J Thorac Cardiovasc Surg. 2014; 147: 590-597. ... Fetch This Document
Early Experience With Implantation Of The New Biological ...
With the new biological valve Trifecta (St. Jude Medical, Inc.). Material and methods: of the St. Jude Medical Trifecta Pericardial Aortic Valve Bioprosthesis. Pre-New York 2010. 9. Trifecta Valve – 2011 Clinical Compendium, One Year Data. ... Fetch Document
Mechanical Prosthetic Mitral Valve In Plax View.avi - YouTube
Mechanical Prosthetic Mitral Valve in Plax view.avi ST JUDES MECHANICAL HEART VALVE - Duration: 7:19. Prajeesh TC 51,415 views. 7:19 Animated Mechanical Aortic Valve - Duration: 0:37. PHRM203 53,935 views. 0:37 ... View Video
The Magna Ease Bioprosthesis Has A Lower Profile Height Than ...
Magna ease periCardial aortiC bioprosthesis the magna ease bioprosthesis has a lower profile height than the trifecta bioprosthesis The Magna Ease bioprosthesis has a low profile designed to ease St. Jude Medical indicated that the dimensions are reference dimensions. ... View Document
NOVEMBER 2010 CARDIAC SURGERY ID CATALOGUE 5
Cardiac Surgery International Catalogue GMCSD174EN Trifecta, ST. JUDE MEDICAL, Muneretto C, et al. Italian Multicenter Study Group for the St. Jude Medical Hemodynamic Plus Aortic Valve Prosthesis. Clinical evaluation of St. Jude Medical Hemodynamic Plus versus standard aortic ... View Full Source
PERICARDIAL AORTIC BIOPROSTHESIS - Edwards Lifesciences
PERICARDIAL AORTIC BIOPROSTHESIS Design • Mathematically modeled bioengineered design is intended to optimize previously implanted aortic valve prosthesis that is no longer functioning adequately and requires replacement. ... Doc Viewer
CoreValve - Medtronic Heart
St. Jude Medical Trifecta™ Valvexii Valve Size 19 mm 21 mm 23 mm 25 mm 27 mm 29 mm 31 mm Diameter 17 19 21 23 25 Height 15 16 17 18 19 Corresponding CoreValve* ... Retrieve Doc
Predicting Heart Failure Recurrence After Aortic Valve ...
Predicting Heart Failure Recurrence after Aortic Valve Replacement using a Competing Risk Model Background Congestive Cheung A, et al. The St Jude Medical Trifecta aortic pericardial valve: Results from a global, multicenter, prospective clinical study. J Thorac Cardiovasc Surg. 2013. doi:10 ... Retrieve Here
Aortic valve Replacement - Wikipedia, The Free Encyclopedia
Aortic valve replacement is a procedure in which a patient's failing aortic valve is replaced with an artificial heart valve. The aortic valve can be affected by a range of diseases; the valve can either become leaky (aortic insufficiency / regurgitation) ... Read Article
The Porcine valve Type Predicts Obstructive Thrombosis Beyond ...
The porcine valve type predicts obstructive thrombosis beyond the first the aortic valve position, 749 (43%) were porcine and 1002 Lifesciences, Irvine, California; Trifecta®, St. Jude Medical, St. Paul, Minnesota; or Mitroflow®, Sorin, Milano, ... Fetch Full Source
Suture Technique Does Not Affect Hemodynamic Performance Of ...
Suture technique does not affect hemodynamic performance of the small supra-annular Trifecta bioprosthesis Trifecta bioprosthesis (St Jude Medical Inc, St Paul, mandated clinical trial of the small supra-annular Trifecta (St Jude Medical Inc) aortic valve bovine bioprosthesis. ... Retrieve Content
WHAT CAN THE SURGEON DO TO AVOID PATIENT-PROSTHESIS MISMATCH
WHAT CAN THE SURGEON DO TO AVOID PATIENT-PROSTHESIS MISMATCH ( PPM )? Dr. Ibrahim Khadragi Trifecta St Jude Pericardial Stented Supra-annular Valve St Jude Aortic Regent Mechanical Valve 17-mm ... View Doc
Early Effects Of Transcatheter aortic valve Implantation And ...
Early effects of transcatheter aortic valve implantation and aortic Supported by unencumbered research grants from St Jude Medical and Edwards Lifesciences. Disclosures: St Paul, Minn), and Trifecta (St Jude Medical Inc). ... Retrieve Document
Heart Valve Replacements: Deciding Which To Use
Heart Valve Replacements. The Texas Heart Institute at St. Luke’s Episcopal Hospital. Accessed Heart Valve Surgery and Blood Thinners: What You Should Know; Treating Aortic Regurgitation; Heart Valve Diseases; All About Open Heart Surgery and Recovery; Treatment Choices for ... Read Article
Cardiac Surgery A4 - Br.sjm.com
Of the St. Jude Medical Regent™ Aortic Valve Prosthesis. J Heart Valve Dis 2001; 10:436-442. 12. Bartels C, Sievers, H. Successful Dilatation of the Small Aortic Root for Implan- St. Jude Medical, Trifecta Valve Clinical Report - January, 2010. EOA values ... Access Full Source
Sutureless Prostheses And Less Invasive Aortic Valve ...
Sutureless Prostheses and Less Invasive Aortic Valve Replacement: Just an Issue of Clamping Time? Marco Vola, MD, PhD, Salvatore Campisi, MD, Antoine Gerbay, MD, Jude Epic and Trifecta (St Jude Medical, St Paul, MN), and ... Fetch Content
Patient-Valve Mismatch: Surgical Considerations
Patient-Valve Mismatch: Surgical Considerations Benoit de Varennes MD, MSc, FRCS(C) McGill University Health Centre The St Jude Medical Trifecta aortic pericardial valve: Results from a global, multicenter, prospective clinical study. J Thorac Cardiovasc Surg 2014; 147: 590- ... Retrieve Doc
No comments: